TeraTurtle LTO WATERPROOF Premium Protective Case - 10 Capacity (with jewel case) 07-509003
Add-ons
TeraTurtle LTO WATERPROOF Premium Protective Case - 10 Capacity (with jewel case) 07-509003
This waterproof heavy duty case stores 10 LTO tapes in their plastic jewel boxes and provides protection against the key problems that cause data loss:
- physical damage from impact
- tape distortion from wound-in debris
- fast and large changes in temperature and humidity
Features
- Waterproof
- Superior cushioning and no exposed foam or debris generating agents
- Individual slots for each tape
- Airtight
- ATA Impact certified
- Stainless steel hardware
- Double movement latches prevent accidental opening
- 2x padlock slots
- Lifetime warranty
Shipping dims: 13" x 11" x 7"
Shipping weight: 4 lbs
Compatible Locks
- Turtle Lock - 5020
- Turtle Lock - 6000
- Turtle Lock - TSA
Certifications
☑ Waterproof IPX7
☑ Dustproof IP6X
☑ Impact ATA 300
☑ Drop Test ASTM D-4169 CC-18
☑ Vibration STM D-4169 DC-18
☑ Rainfall ASTM D-4169 DCc-18
☑ Immersion MIL-STD-810F
Descriptions of Tests
ATA Specification 300 Category 1
Airline transport container suitable for a minimum of 100 airline trips
Impact Resistance Test; samples were exposed to impact using a bar weighing 13.2lbs with a hemispherical end of 3.2cm. Bar was dropped with its longitudinal axis vertical on to each sample’s weakest point from a height of 0.5m. Samples were conditioned to a temperature of -20°C before impact exposure.
ASTM D-4169 DC-18
Level 1 Schedule A Handling (Manual)
Drop tests - a series of drops on each edge, corner and face of the case from a height of no less than 48cm(19”) and with loads of 6.8-31.8kg(15-70lbs) determined by case size. Samples were conditioned at lab ambient conditions and then temperatures of -28°C and +60°C for a minimum of 3 hours at each condition.
ASTM D-4169 DC-18
Level 1, Schedule F loose load vibration
Vibration - The cases are tested using test method D-999 to determine the ability to withstand the repetitive shocks occurred during transportation of loose loads.
ASTM D-4169 DC-18
Level 1, Schedule H Environmental Hazard Rainfall
Simulated rainfall for 2hrs at a rate of 10cm/hr (4”). Samples were conditioned to -20 degrees C and +52 degrees C.
MIL-STD-810F
Method 512.4
Immersion - The case is submerged in a basin of water to a depth of 1 meter (3.28 ft) to the top most part of the case for 30 minutes. The case is heated to 10 degrees F higher than the temperature of the water.
IP 67 ingress protection
6- Total protection from dust
7- Protected against the effects of immersion between 15cm (5.9”) and 1m (39.37”)